Déscription
The OMEGA™ DR130 Series portable hybrid recorder offers high speed scanning of 20 points/2 sec and high speed recording. This versatile recorder weighs less than 10 kg (21 lb). Operation is simple, yet powerful optional computing functions and floppy disk enhance the unit’s performance. The DR130 uses a high breakdown voltage solid state relay that permits high scan speed and long relay life without noise.
Specifications Number of Inputs: Up to 10 or 20 points A/D Resolution: ±20,000 Reference Junction Compensation Error: ±1°C (1.8°F) (R, S, B, C, W), ±0.5°C/0.9°F (K, J, T, E, N, U, L CHROMEGAR vs. Au7% Fe) Scan Cycle Time: 2 to 60 sec selectable (2, 3, 4, 5, 6, 10, 12, 15, 20, 30, 60 sec) A/D Integration Time: 20 msec (50 Hz), 16.7 msec (60 Hz), and 100 msec (10 Hz), (50/60 Hz) selectable Input Impedance: >10 M on 2 V or lower ranges and T/C; approx. 1 M on 6 V or higher ranges Input Bias Current: <10 nA Thermocouple Burnout Protection: ON or OFF selectable for each channel Temperature Coefficient: zero drift; 0.01% of range/°C, full span; 0.01% of range/°C Max. Input Voltage: ±10 Vdc (60 V on 6 V or greater ranges) Common Mode Voltage: 250 Vrms ac (50/60Hz) Common Mode Rejection: 120 dB (50 or 60 Hz ±0.1%) Normal Mode Rejection: 40 dB (50 or 60 Hz ±0.1%) Max between Chan: 150 Vrms ac (50/60 Hz except RTD) Printing Technique: Raster scan using a wire-dot printer and 10-colour ribbon Effective Recording Span: 150 mm (5.9"), analogue Chart: Z-fold chart, 230 mm (9") width, 20 m (65.5') long Recording Resolution: ±0.1 mm Recording Accuracy: measurement accuracy plus (±0.2% of effective recording span) Printout Format: analogue trend/ analogue trend plus digital datalogging Chart Speed: 1 to 1500 mm/hr Chart Drive: pulse motor drive Chart Speed Accuracy: ±0.1% Recording Modes: Normal, print on alarm, chart speed/interval changes at set alarm Standard Printing Functions: engineering units (up to 6 alphanumerics), tag number (up to 7 alphanumerics), alarms (channel number, alarm types, and the time of alarm On/Off), scale markings (0/100%, 0/50/100%, or 20% steps), program list, manual, message (max. 16 characters), and header (60 characters x 5 lines) DISPLAY AND CONTROLS Display: 5 x 7 dot matrix, 3 row, vacuum fluorescent; 1st row 22 large, 2nd & 3rd 40 small characters Data Display: measured data (tag number, channel number, alarm status, measured value, engineering unit), bargraph, clock, alarm status, relay status, programming data, battery status, and recording format (Trend/Log) Scaling Range: -30,000 to +30,000 Calculation: Difference between any channels or moving average for every 2 to 64 scans |
Internal Memory: 10 yr lithium battery back up; 512 KB SRAM with floppy disc drive option Optional Memory: 3.5 inch floppy; 1.4 MB or 720 K Alarms: up to 4/channel Outputs: 12 max with -A4 & -R1 opt Alarm Types: high (H), low (L), high rate of change (RH), low rate of change (RL), delta high (H) and delta low (L) Recording: Trend mode: CH# alarm types, and On/Off times in the right margin; logging mode: CH# and alarm types at the start of measured data Alarm Acknowledgement: pressing the ACK key stops the alarm display flashing and resets the dedicated common relay output Alarm Reset: hold type relay output by pressing the RESET key Display: flashing display can be obtained for 20 point alarm status (channels 1 to 20) plus one common point for computing channels (channels 31 to 60) GENERAL Ambient Operating Temperature: 5 to 40°C (40 to 104°F) Humidity Range: 20 to 80% Power Supply: 90 to 250 Vac, 50 or 60 Hz ±2% Power Consumption: approx 130 VA Clock: with calendar function Input Terminals: clamped input terminal block (standard) and screw input terminal block (optional) Mounting: desktop or flush panel MOST mounting (can be inclined up to 30° backward from vertical) Dimensions: 221 H x 338 W x 335 mm D (834 x 13516 x 13316") Weight: 9.3 kg (20.5 lb) approx. OPTIONAL FEATURES Alarm Outputs (-A4 option): 10 points, contact rating 30 Vdc or 250 Vac, 2 A resistive. AND, OR, REFLASH, or latching option type output Remote Control (-R1 option): Through the contact input, start/stop, chart speed/interval change, manual printout, message recording, digital recording in the trend mode, writing on the memory card, and loading trigger available. Input signal; TTL-level, open collector, and contact status,. plus 2 alarm outputs. GPIB Interface (-C1 option): conforms to IEEE standard 488-1978 RS-232C Interface (-C2 option): conforms to EIA RS-232C Computation (-M1 option): Functions: +, -, x, =, SQR (square root), ABS (absolute value), LOG (common logarithm), EXP (exponential), logic (AND, OR, NOT, XOR), CLOG & TLOG (group or channel; max, min, avg, totals, max minus min) Software: Runs on Windows95, 98 or NT 4.0. |
Input Type and Range | Measurement (Digital Display and Printout) | |
Accuracy | Resolution | |
±20.000 mVdc ±60.00 & ±200.00 ±2.0000 Vdc ±6.000 & ±20.000 ±50.00 Vdc | ±(0.05% of rdg + 5 digits) ±(0.05% of rdg + 2 digits) ±(0.05% of rdg +2 digits) ±(0.05% of rdg +2 digits) ±(0.05% of rdg +2 digits) | 1 µV 10 µV 100 µV 1 mV 10 mV |
R 0 to 1760°C S 0 to 1760°C B 0 to 1820°C | ±(0.05% of rdg + 1°C) however: R,S: 0 to 100°C ±3.7°C 100 to 300°C ± 1.5°C and B: 400 to 600°C ± 2°C | 0.1°C |
K -200 to 1370°C | ± (0.05% of rdg + 0.7°C) however: -200 to -100°C ± (0.05% of rdg + 1°C) | 0.1°C |
E -200 to 800°C J -200 to 1100°C T -200 to 400°C J DIN (L) -200 to 900°C T DIN (U) -200 to 400°C | ±(0.05% of rdg + 0.5°C) however: J, L DIN: -200 to -100°C ±(0.05% of rdg + 0.7°C) | |
Kp vs Au7Fe 0 to 300K | ±(0.05% of rdg + 0.7K) | 0.1K |
N 0 to 1300°C | ±(0.05% of rdg + 0.7°C) | 0.1°C |
C (W) 0 to 2315°C | ±(0.05% of rdg + 1°C) | |
PT100 -200 to 600°C | ±(0.05% of rdg + 0.3°C) | 0.1°C |
PT100 -140 to 150°C | ±(0.05% of rdg + 0.3°C) | 0.01°C |
Ni100/120 -60 to 180°C | ±(0.05% of rdg + 0.3°C) | 0.1°C |
Cu10Ω -200 to 300°C | ±(0.2% of rdg + 0.7°C) | 0.1°C |
Manuels de Produit: