Cookies sur les sites Web Omega
Nous utilisons des cookies sur ce site Web. Ces cookies sont indispensables au bon fonctionnement de notre site.
Si vous continuez sans modifier vos paramètres, nous supposerons que vous êtes heureux de recevoir tous les cookies de notre site Web.
Pour de plus amples informations à ce sujet, veuillez cliquer ici
Fermer
Panier  |  Contact  | 
NUMÉRO VERT 0805 541 038
INTERNATIONAL+33 01 57 32 48 17
Layer N Banner

CLAMP-ON ULTRASONIC ENERGY FLOWMETER - Discontinued

FDT-40E Series

CLAMP-ON ULTRASONIC ENERGY FLOWMETER | FDT-40E Series

CLAMP-ON ULTRASONIC ENERGY FLOWMETER

Garantie 1 an CE
  • Bi-Directional Flow/Energy Measurement
  • Rugged, Aluminum Enclosure
  • Rate and Total Backlit Display
  • 4 to 20 mA and Dual Alarm Outputs
  • USB Programming Port
  • RS485 MODBUS® Network Connection

Déscription

Discontinued, no replacement.

.
Find how a Ultrasonic flow meter works on this link.

FDT-40E Series ultrasonic flow and energy meters clamp on to the outside of pipes and do not come in contact with the internal liquid. The technology has inherent advantages over alternate devices including: low-cost installation, no pressure head loss, no moving parts to maintain or replace, no fluid compatibility issue, and a large, bi-directional measuring range that ensures reliable readings even at very low and high flow rates. FDT-40E Series is available in a variety of configurations that permit the user to select a meter with features suitable to meet particular application requirements.

Specifications
System
Liquid Types: Most clean liquids or liquids containing small amounts of suspended solids or gas bubbles
Velocity Range: Bi-directional to greater than 40 FPS (12 MPS)
Flow Accuracy:
    Larger Than 50 mm (2"): ±1% of reading or ±0.01 FPS (0.003 MPS), whichever is greater
    25 to 50 mm (1 to 2"): ±1% of reading or ±0.04 FPS (0.012 MPS), whichever is greater
    19 mm (¾") and Smaller: ±1% of full scale
Temperature Accuracy:
    Absolute: 0.25°C (0.45°F)
    Difference: 0.1°C (0.18°F)
Energy Temperature Range: 0 to 100°C (32 to 212°F)
Sensitivity Flow: 0.001 FPS (0.0003 MPS)
Temperature: 0.025°C (0.05°F)
Repeatability: 0.5% of reading Transmitter
Power Requirements (AC): 95 to 264 Vac 47 to 63 Hz @ 17 VA maximum standard, 20 to 28 Vac 47 to 63 Hz @ 0.35 A maximum (“-24VAC” models), 10 to 28 Vdc @ 5 W maximum (“-VDC” models)
Protection: Auto resettable fuse, reverse polarity and transient suppression
Display: Two line LCD, LED backlit; top row 18 mm (0.7") height, 7-segment; bottom row 9 mm (0.35") height, 14-segment
Icons: RUN, PROGRAM, RELAY1, RELAY2
Flow Rate Indication: 8-digit positive, 7-digit negative maximum; auto decimal, lead zero blanking
Flow Totalizer: 8-digit positive, 7-digit negative maximum (re-set via keypad press, software, network command or momentary contact closure
Enclosure NEMA 4 (IP65) Construction: Powder-coated aluminum, polycarbonate, stainless steel, polyurethane, nickel-plated steel mounting brackets
Size (Electronic Enclosure Only): 152 W x 112 H x 56 mm D (6.0 x 4.4 x 2.2")
Conduit Holes: (2) ½ NPT female (1) ¾ NPT female
Temperature: -40 to 85°C (-40 to 185°F)
RTD: Platinum 385, 1000O, 3-wire
Configuration: Via optional keypad or PC running software (Note: not all configuration parameters are available from the keypad – i.e. flow and temperature calibration and advanced filter settings)
Engineering Units Flow Meter: Feet, gallons, cubic feet, million gallons, barrels (liquid and oil), acre-feet, lbs, meters, cubic meters, liters, million liters, kg
Engineering Units Energy Meter: BTU, MBTU, MMBTU, Tons
Inputs/Outputs USB 2.0: For connection of a PC running configuration utility
    RS485: MODBUS RTU command set
    4 to 20 mA: 12-bit, internal power, can span negative to positive flow/energy rates
Transducers
Construction
    Standard (FDT-41 thru 46): NEMA 6 (IP67), PVC, PEI, Nylon cord grip, PVC cable jacket
    Temperature: -40 to 85°C (-40 to 185°F)
    FDT-41 thru 46 with “-HT” option, FDT-47 and FDT-48: NEMA 6 (IP67), CPVC, PEI, Nylon cord grip, PVC cable jacket
    Temperature: -40 to 121°C (-40 to 250°F)
    FDT-47 “-HT”: NEMA 6 (IP67), PTFE, polyimide, Nickel-plated brass cord grip, PFA cable jacket
    Temperature: -40 to 176°C (-40 to 350°F)
Frequency:
    FDT-41 thru 46: 2 MHz
    FDT-47: 1 MHz
    FDT-48: 500 KHz
Cables: RG59 coaxial, 75 Ω or twin axial, 78 Ω (optional armored conduit)
Cable Length: Standard 6 m (20') [300 m (990') maximum in 3 m (10') increments; submersible conduit limited to 30 m (100') for transducers]
Software Utilities Utilized to configure, calibrate and troubleshoot flowmeters. Connection via USB A/B cable; software is compatible with Windows 2000, Windows XP, Windows Vista® and Windows® 7
RS485 Network All FDT-40 meters come equipped with RS485 drivers and utilize a MODBUS RTU command set (data can be returned in single-precision, doubleprecision, integer or floating point values). Up to 126 units products can be run on a single daisy-chain network and be individually queried for flow rate, positive flow accumulator, negative flow accumulator and signal strength. Flow accumulators can be cleared at discrete addresses or globally. The RS485 network is also compatible with direct to Excel, application.
Placez votre commande(Veuillez spécifier la référence du produit)

Ce que d'autres personnes ont acheté: quand vous voyez cette icône, cliquez dessus pour afficher une liste des produits que d'autres personnes ont achetés en plus de ce modèle.

Code d'article/ Desc.
Qté
Déscription
  
FDT-40E
Consultez le Service de ventes  
Stock: 
 
 
Energy flowmeter display 95 to 264 Vac, temperature range 0 to 100°C (32 to 212°F)
  
FDT-40E-VDC
Consultez le Service de ventes  
Stock: 
 
 
Energy flowmeter display 10 to 28 Vdc, temperature range 0 to 100°C (32 to 212°F)
  
FDT-40E-24VAC
4,219.00
Stock: 4 semaines
 
Energy flowmeter display 24 Vac, temperature range 0 to 100°C (32 to 212°F)
  
FDT-40E-HT
Consultez le Service de ventes  
Stock: 
 
 
Energy flowmeter display 95 to 264 Vac, temperature range -40 to 177°C (-40 to 350°F)
  
FDT-40E-VDC-HT
4,059.18
Stock: 4 semaines
 
Energy flowmeter display 10 to 28 Vdc, temperature range -40 to 177°C (-40 to 350°F)
  
FDT-40E-24VAC-HT
4,219.00
Stock: 4 semaines
 
Energy flowmeter display 24 Vac, temperature range -40 to 177°C (-40 to 350°F)
Accessory Remote Transducers (Display Sold Separately)
Remote Transducers for ANSI Pipe
  
FDT-41-ANSI
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 1/2" ANSI pipe
  
FDT-42-ANSI
€683.76
Stock: 1 semaine
 
Transducer for 3/4" ANSI pipe
  
FDT-43-ANSI
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 1" ANSI pipe
  
FDT-44-ANSI
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 1 1/4" ANSI pipe
  
FDT-45-ANSI
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 1 1/2" ANSI pipe
  
FDT-46-ANSI
€794.94
Stock: En stock
 
Transducer for 2" ANSI pipe
  
FDT-41-ANSI-100FT
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 1/2" ANSI pipe with 100 ft of cable
  
FDT-42-ANSI-100FT
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 3/4" ANSI pipe with 100 ft of cable
  
FDT-43-ANSI-100FT
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 1" ANSI pipe with 100 ft of cable
  
FDT-44-ANSI-100FT
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 1 1/4" ANSI pipe with 100 ft of cable
  
FDT-45-ANSI-100FT
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 1 1/2" ANSI pipe with 100 ft of cable
  
FDT-46-ANSI-100FT
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 2" ANSI pipe with 100 ft of cable
  
FDT-41-ANSI-HT
€1,226.32
Stock: 7 semaines
 
High temperature transducer for 1/2" ANSI pipe
  
FDT-42-ANSI-HT
€1,226.00
Stock: 7 semaines
 
High temperature transducer for 3/4" ANSI pipe
  
FDT-43-ANSI-HT
€1,295.25
Stock: 7 semaines
 
High temperature transducer for 1" ANSI pipe
  
FDT-44-ANSI-HT
€1,296.00
Stock: 7 semaines
 
High temperature transducer for 1 1/4" ANSI pipe
  
FDT-45-ANSI-HT
€1,295.25
Stock: 7 semaines
 
High temperature transducer for 1 1/2" ANSI pipe
  
FDT-46-ANSI-HT
€1,375.00
Stock: 7 semaines
 
High temperature transducer for 2" ANSI pipe
  
FDT-41-ANSI-HT-100FT
€1,517.00
Stock: 7 semaines
 
High temperature transducer for 1/2" ANSI pipe with 100 ft of cable
  
FDT-42-ANSI-HT-100FT
€1,517.00
Stock: 7 semaines
 
High temperature transducer for 3/4" ANSI pipe with 100 ft of cable
  
FDT-43-ANSI-HT-100FT
€1,573.00
Stock: 7 semaines
 
High temperature transducer for 1" ANSI pipe with 100 ft of cable
  
FDT-44-ANSI-HT-100FT
€1,573.00
Stock: 7 semaines
 
High temperature transducer for 1 1/4" ANSI pipe with 100 ft of cable
  
FDT-45-ANSI-HT-100FT
€1,573.00
Stock: 7 semaines
 
High temperature transducer for 1 1/2" ANSI pipe with 100 ft of cable
  
FDT-46-ANSI-HT-100FT
€1,627.00
Stock: 7 semaines
 
High temperature transducer for 2" ANSI pipe with 100 ft of cable
Remote Transducers for Copper Pipe
  
FDT-41-CP
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 1/2" Copper pipe
  
FDT-42-CP
€683.76
Stock: 1 semaine
 
Transducer for 3/4" Copper pipe
  
FDT-43-CP
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 1" Copper pipe
  
FDT-44-CP
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 1 1/4" Copper pipe
  
FDT-45-CP
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 1 1/2" Copper pipe
  
FDT-46-CP
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 2" Copper pipe
  
FDT-41-CP-100FT
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 1/2" Copper pipe with 100 ft of cable
  
FDT-42-CP-100FT
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 3/4" Copper pipe with 100 ft of cable
  
FDT-43-CP-100FT
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 1" Copper pipe with 100 ft of cable
  
FDT-44-CP-100FT
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 1 1/4" Copper pipe with 100 ft of cable
  
FDT-45-CP-100FT
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 1 1/2" Copper pipe with 100 ft of cable
  
FDT-46-CP-100FT
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 2" Copper pipe with 100 ft of cable
  
FDT-41-CP-HT
€1,226.00
Stock: 7 semaines
 
High temperature transducer for 1/2" Copper pipe
  
FDT-42-CP-HT
€1,226.00
Stock: 7 semaines
 
High temperature transducer for 3/4" Copper pipe
  
FDT-43-CP-HT
€1,296.00
Stock: 7 semaines
 
High temperature transducer for 1" Copper pipe
  
FDT-44-CP-HT
€1,296.00
Stock: 7 semaines
 
High temperature transducer for 1 1/4" Copper pipe
  
FDT-45-CP-HT
€1,296.00
Stock: 7 semaines
 
High temperature transducer for 1 1/2" Copper pipe
  
FDT-46-CP-HT
€1,375.00
Stock: 7 semaines
 
High temperature transducer for 2" Copper pipe
  
FDT-41-CP-HT-100FT
€1,517.00
Stock: 7 semaines
 
High temperature transducer for 1/2" Copper pipe with 100 ft of cable
  
FDT-42-CP-HT-100FT
€1,517.00
Stock: 7 semaines
 
High temperature transducer for 3/4" Copper pipe with 100 ft of cable
  
FDT-43-CP-HT-100FT
€1,573.00
Stock: 7 semaines
 
High temperature transducer for 1" Copper pipe with 100 ft of cable
  
FDT-44-CP-HT-100FT
€1,573.00
Stock: 7 semaines
 
High temperature transducer for 1 1/4" Copper pipe with 100 ft of cable
  
FDT-46-CP-HT-100FT
€1,627.00
Stock: 7 semaines
 
High temperature transducer for 2" Copper pipe with 100 ft of cable
  
FDT-45-CP-HT-100FT
€1,573.00
Stock: 7 semaines
 
High temperature transducer for 1 1/2" Copper pipe with 100 ft of cable
Remote Transducers for Tubing
  
FDT-41-TUBE
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 1/2" tubing
  
FDT-42-TUBE
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 3/4" tubing
  
FDT-43-TUBE
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 1" tubing
  
FDT-44-TUBE
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 1 1/4" tubing
  
FDT-45-TUBE
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 1 1/2" tubing
  
FDT-46-TUBE
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 2" tubing
  
FDT-41-TUBE-100FT
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 1/2" tubing with 100 ft of cable
  
FDT-42-TUBE-100FT
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 3/4" tubing with 100 ft of cable
  
FDT-43-TUBE-100FT
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 1" tubing with 100 ft of cable
  
FDT-44-TUBE-100FT
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 1 1/4" tubing with 100 ft of cable
  
FDT-45-TUBE-100FT
€1,151.00
Stock: 7 semaines
 
Transducer for 1 3/4" tubing with 100 ft of cable
  
FDT-45-TUBE-100FT
€1,151.00
Stock: 7 semaines
 
Transducer for 1 1/2" tubing with 100 ft of cable
  
FDT-46-TUBE-100FT
Consultez le Service de ventes  
Stock: 
 
 
Transducer for 2" tubing with 100 ft of cable
  
FDT-41-TUBE-HT
€1,226.00
Stock: 7 semaines
 
High temperature transducer for 1/2" tubing
  
FDT-42-TUBE-HT
€1,226.00
Stock: 7 semaines
 
High temperature transducer for 3/4" tubing
  
FDT-43-TUBE-HT
€1,296.00
Stock: 5 semaines
 
High temperature transducer for 1" tubing
  
FDT-44-TUBE-HT
€1,296.00
Stock: 7 semaines
 
High teperature transducer for 1 1/4" tubing
  
FDT-45-TUBE-HT
€1,296.00
Stock: 7 semaines
 
High teperature transducer for 1 1/2" tubing
  
FDT-46-TUBE-HT
€1,375.00
Stock: 5 semaines
 
High temperature transducer for 2" tubing
  
FDT-41-TUBE-HT-100FT
€1,517.00
Stock: 7 semaines
 
High temperature transducer for 1/2" tubing with 100 ft of cable
  
FDT-42-TUBE-HT-100FT
€1,517.00
Stock: 7 semaines
 
High temperature transducer for 3/4" tubing with 100 ft of cable
  
FDT-43-TUBE-HT-100FT
€1,573.00
Stock: 7 semaines
 
High temperature transducer for 1" tubing with 100 ft of cable
  
FDT-44-TUBE-HT-100FT
€1,573.00
Stock: 7 semaines
 
High temperature transducer for 1 1/4" tubing with 100 ft of cable
  
FDT-45-TUBE-HT-100FT
€1,573.00
Stock: 7 semaines
 
High temperature transducer for 1 1/2" tubing with 100 ft of cable
  
FDT-46-TUBE-HT-100FT
€1,627.00
Stock: 7 semaines
 
High temperature transducer for 2" tubing with 100 ft of cable
RemoteTransducers
Cliquez pour agrandir / réduire une liste d'achat connexeFDT-47
FDT-47
€1,026.20
Stock: 1 semaine
 
Transducer for 2 to 24" pipe
  
FDT-47-100FT
€1,313.04
Stock: 5 semaines
 
Transducer for 2 to 24" pipe with 100 ft of cable
  
FDT-47-HT
€4,020.00
Stock: 7 semaines
 
High temperature transducer for 2 to 24" pipe
  
FDT-47-HT-100FT
€4,306.00
Stock: 7 semaines
 
High temperature transducer for 2 to 24" pipe with 100 ft of cable
  
FDT-48
€1,647.00
Stock: 7 semaines
 
Transducer for pipes over 24"
  
FDT-48-100FT
€1,937.00
Stock: 7 semaines
 
Transducer for pipe over 24" with 100 ft of cable
Accessories
  
FDT-40-PC-CABLE
€74.83
Stock: 5 semaines
 
Optional USB PC programming cable
  
FDT-40-CABLE GLAND
€39.22
Stock: 1 semaine
 
Optional cable gland
  
FDT-40-BHC
€103.82
Stock: 4 semaines
 
Brad Harrison connector for the FDT-40 Series
  
FDT-40-RTDCONN
€108.82
Stock: 5 semaines
 
RTD Pig Tail (connection adapter)
  
FDT-40-RTD1
€680.05
Stock: 5 semaines
 
RTD kit, clamp-on, 130C, 1000Ω 6.1 m (20')
  
FDT-40-RTD2
€853.13
Stock: 1 semaine
 
RTD kit, clamp-on, 200C, 1000Ω 6.1 m (20')
  
FDT-40-RTD3
€1,251.00
Stock: 5 semaines
 
RTD kit, insertion, 3 x 1/4", 126C, 1000Ω Platinum RTD
Cliquez pour agrandir / réduire une liste d'achat connexeFDT-GREASE
FDT-GREASE
€76.53
Stock: 1 semaine
 
Replacement acoustic couplant 150 g (5.3 oz)
  
FDT-HT-GREASE
€171.95
Stock: 1 semaine
 
High temperature acoustic couplant 56 g (2 oz)
Cliquez pour agrandir / réduire une liste d'achat connexeFDT-NS-GREASE
FDT-NS-GREASE
€76.53
Stock: En stock
 
Non-silicone acoustic couplant 79 g (2.8 oz)
Tous les Montants indiqués Dans EUR
Notez: Comes complete with operator’s manual. Transducers come with mounting gel.

Transducers sold separately.


 Constructeur de référence

Construisez votre numéro de pièce ci-dessous
Descriptions des options de:


(1) Pipe and Tubing Sizes Select:
41 pour 1/2 Inch
42 pour 3/4 Inch
43 pour 1 Inch
44 pour 1 1/4 Inch
45 pour 1 1/2 Inch
46 pour 2 Inch
47 pour 2 to 24 Inch
48 pour Pipes over 24 inch

(2) Pipe and Tubing Material Select:
ANSI pour ANSI pipe
CP pour Copper pipe
TUBE pour Plastic tubing

(3) High Temperature Select:
Rien (champ vide de congé) pour None
-HT pour High temp transducers

(4) Cable Length Select:
Rien (champ vide de congé) pour Standard 6 m (20 feet)
-100FT pour 30 m (100 feet)
Notez: Toutes les combinaisons peuvent ne pas être valables, vérifiez la fiche technique pour les références valables.
We noticed you are from the US. Visit your local site for regional offers and live support.