Layer N Banner

Bridge/Strain Gauge Data Logger  - Discontinued

OM-CP-BRIDGE110-10

 | OM-CP-BRIDGE110-10

5 ans de garantie CE
  • The OM-CP-BRIDGE110 series has been discontinued. Please see the OM-CP-BRIDGE101A as a possible alternative or contact our Engineering department.

  • 10 Year Battery Life
  • High Speed Download
  • Programmable Start Time
  • Miniature Size
  • Real Time Operation
  • Reads in Microstrain and Engineering Units
  • Use with Strain Gauges, Load Cells, Pressure Transducers, Torque Sensors, Load Bolts and Position Transducers
Instrumentation pour la mesure de pression et tension - Voir Les Produits Associés

Déscription

The OM-CP-BRIDGE110 is a miniature battery powered, stand alone, bridge/strain gauge data logger. The OM-CP-BRIDGE110 features a real-time clock module that extends the battery life to more than 10 years (15 minute reading rate at 25°C) and allows for high speed downloads. This is an all-in-one compact, portable, easy-to-use device that will measure and record up to 32,767 measurements. The storage medium is non-volatile solid state memory, providing maximum data security even if the battery becomes discharged. The device can be started and stopped directly from your computer and its small size allows it to fit almost anywhere.

The OM-CP-BRIDGE110 makes data retrieval quick and easy. Simply plug it into an available COM port and our user-friendly software does the rest. The software converts your PC into a real time strip chart recorder. Data can be printed in graphical or tabular format and can be exported to a text or Microsoft Excel file.

Specifications
Input Connection: 6-position removable screw terminal
Input Impedance: 1 Mohm during acquisition, low impedance when inactive
Reference Voltage Output: 2.5 Vdc, 2.5 mA (1 kohm) maximum load
Maximum Input Signal Impedance: 5 kohm(350 ohm sensors may be used with series resistors to produce >1 Kohm; 120 ohm gauges may be used in half and quarter bridge configurations)
Temperature Effect on Span and Offset: <25 µV over -40 to 80°C
Engineering Units: Stored in device, user may define any desired scale and offset from ±1.000E-31 to ±9.999E+31
Start Time: Start time and date are programmable through software up to six months in advance
Real Time Recording: Device may be used with PC to monitor and record data in real time
Memory: 32,767 readings
Recording Interval: 1 reading every 2 seconds to 1 every 12 hours
Calibration: Digital calibration through software
Calibration Date: Automatically recorded within device to alert user when calibration is required
Battery Life: 10 years at 15 min reading rate, 25°C
Power: 3.6 V lithium battery included
Data Format: Date and time stamped, %, ppm; e, µe, V, mV, µV engineering units specified through software
Time Accuracy: ±1 minute per month at 20°C to 30°C)
Computer Interface: PC serial, RS-232C COM or USB (interface cable required); 56,600 baud
Software: Windows 95/98/ME/NT/2000/XP
Operating Environment: -40 to 80°C (-40 to 176°F) 0 to 95% RH non-condensing
Dimensions: 42 H x 68 W x 20 mm D (1.7 x 2.7 x 0.8")
Weight: 60 g (2 oz) The OM-CP-BRIDGE110 series has been discontinued. Please see the OM-CP-BRIDGE101A as a possible alternative or contact our Engineering department.

Placez votre commande(Veuillez spécifier la référence du produit)

Ce que d'autres personnes ont acheté: quand vous voyez cette icône, cliquez dessus pour afficher une liste des produits que d'autres personnes ont achetés en plus de ce modèle.

Code d'article/ Desc.
Qté
Déscription
  
OM-CP-BRIDGE110-10
Consultez le Service de ventes  
Stock: 
 
 
Bridge input datalogger (±10 mV input range)
  
OM-CP-BRIDGE110-25
Consultez le Service de ventes  
Stock: 
 
 
Bridge input datalogger (±25 mV input range)
  
OM-CP-BRIDGE110-100
Consultez le Service de ventes  
Stock: 
 
 
Bridge input datalogger (±100 mV input range)
  
OM-CP-BRIDGE110-1000
Consultez le Service de ventes  
Stock: 
 
 
Bridge input datalogger (±1000 mV input range)
Accessories
Cliquez pour agrandir / réduire une liste d'achat connexeOM-CP-IFC110
OM-CP-IFC110
Consultez le Service de ventes  
Stock: 
 
 
Windows software and 1.2 m RS-232 cable with DB9F termination
Cliquez pour agrandir / réduire une liste d'achat connexeOM-CP-IFC200
OM-CP-IFC200
168.91
Stock: En stock
 
Windows software and 3.7 m USB interface cable
Cliquez pour agrandir / réduire une liste d'achat connexeOM-CP-BAT105
OM-CP-BAT105
24.16
Stock: En stock
 
Replacement 3.6 V lithium battery
  
OM-CP-CONNECTOR-6
17.06
Stock: 4 semaines
 
Replacement 6 position terminal block connector
Tous les Montants indiqués Dans EUR
Notez: Operator’s manual and communications cable sold seperately. Order OM-CP-IFC200 for USB cable and software, or OM-CP-IFC110 for RS-232 cable and software.
Exemple de commande: (1) OM-CP-IFC200 Windows software and USB interface cable, €168.91 

Manuels de Produit:

Télécharger OM-CP Series - Data Logger and Software User Guide
Télécharger OM-CP Series - Data Logger Quickstart Guide
We noticed you are from the US. Visit your local site for regional offers and live support.