Cookies sur les sites Web Omega Nous utilisons des cookies sur ce site Web. Ces cookies sont indispensables au bon fonctionnement de notre site. Si vous continuez sans modifier vos paramètres, nous supposerons que vous êtes heureux de recevoir tous les cookies de notre site Web. Pour de plus amples informations à ce sujet, veuillez cliquer ici
The OM-CP-RFTCTEMP2000A is a
wireless thermocouple based data
logger with digital display. The device
measures ambient temperatures,
as well as remote temperature via
a thermocouple (sold separately),
making it ideal for monitoring
perishable goods, vaccine storage,
chemicals and more.
Starting, stopping and downloading
from the device are all performed
wirelessly using the
OM-CP-RFC1000-EXT-EUR wireless
transceiver, allowing the user
to spend less time maintaining the
data logger. Data can be provided in
real time back to a central PC, or the
device may be downloaded at
period intervals.
The convenient digital display
provides the current reading for both
channels. Minimum, maximum
and average statistics are also
provided for a convenient snap shot
of the logged data. For instant, out
of range notification, an audible
buzzer as well as LED alarm indicator
notifies users when the temperature
is above or below the user specified
alarm. Through the software, email
and text message alarms can also
be sent.
The OM-CP-RFTCTEMP2000A
also features programmable trigger
settings for applications in which
temperature logging is critical
only above or below a certain
temperature. This information may be
programmed into the device, and the
data logger will only begin to log data
to memory, once the temperature
limit has been exceeded.
The OM-CP-RFTCTEMP2000A can
be used as a single, wireless data
logging system, or expanded into a large scale system, which can
include hundreds of data loggers
measuring a number of areas
(additional wireless loggers and
transceivers may be required).
Data retrieval is simple. Plug the
device into an available USB port
and our easy-to-use software does
the rest. The software converts a PC
into a real-time strip chart recorder.
The data logger software is a
powerful, analytic tool. Data can
be viewed in graphical or tabular
formats and summary and statistics
views are available for further
analysis. The software features
export to Excel®, data annotation,
digital calibration and more.
Specifications Temperature Internal Channel Temperature Range: -20 to 60°C (-4 to 140°F) Temperature Resolution: 0.1°C (0.18°F) Calibrated Accuracy: ±0.10°C (±0.18°F) 0 to 55°C (32 to 131°F) Response Time: 10 minutes free air Remote Channel Thermocouple Types: J, K, T, E, R, S, B, N Thermocouple Connection: mini thermocouple socket (Omega SMP connector) Cold Junction Compensation: Automatic based on internal channel Maximum Thermocouple Resistance: 100 Ω Response Time: 2 minutes to 63% of change Wireless RF Frequency: 2.45GHz IEEE 802.15.4 ultra-low power wireless transceiver with fully bi-directional communication Band: ISM band 2.405-2.48 GHz Output Power: +0dBm typical Range: 610 m (2000') maximum outdoors (line of sight unobstructed); 152 m (500') maximum indoors (typical urban) General Reading Rate: One reading every second up to one every 24 hours Memory: 16,128 per channel LED Functionality:
• Green LED blinks every 5 seconds to indicate unit is logging
• Blue LED blinks every 15 seconds to indicate unit is in wireless mode
• Red LED blinks every 1 second to indicate alarm condition Memory Wrap Around: Yes Start Modes: Immediate start Calibration: Digital calibration through software Calibration Date: Automatically recorded within device Battery Type: 9V lithium battery (included); user replaceable Battery Life: 3 years typical at 1 minute reading rate Data Format:
• For Display: °C or °F
• For Software: Date and time stamped °C, K, °F, or °R Time Accuracy: ±1 minute/month Computer Interface: USB to mini USB, 250,000 baud for standalone operation or OM-CP-RFC1000-EXT required for wireless operation Software: XP SP3/Vista/7/8 (32 and 64-bit) Operating Environment: -20 to 60°C, 0 to 95% RH non-condensing Dimensions: 76.2 H x 88.9 W x 24.1 mm D data logger only Weight: 116 g Enclosure Material: ABS plastic Alarm: Programmable high and low limits for temperature and humidity. Alarm is activated when temperature or humidity reaches or exceeds set limits. Alarm Delay: A cumulative alarm delay may be set in which the device will activate the alarm (via LED) only when the device has recorded a user specified time duration of data. Audible Alarm Functionality: 1 beep per second for reading alarm above/below threshold
† Tous les Montants indiqués Dans EUR I> Notez: Comes complete with 9V lithium battery and mounting bracket. Operator’s manual, Windows software and USB interface cable are included with the OM-CP-RFC1000-EXT-EUR wireless transceiver package (required to operate the data logger, sold separately). Exemple de commande: (1) OM-CP-RFC1000-EXT-EUR Wireless transceiver package includes RF transceiver, USB cable, Windows software and operator’s manual, €252.27