Cookies sur les sites Web Omega Nous utilisons des cookies sur ce site Web. Ces cookies sont indispensables au bon fonctionnement de notre site. Si vous continuez sans modifier vos paramètres, nous supposerons que vous êtes heureux de recevoir tous les cookies de notre site Web. Pour de plus amples informations à ce sujet, veuillez cliquer ici
Click here if you want to know more about anemometers.
The OM-CP-WIND101A is a
complete system to accurately record and measure wind speed.
This low cost wind speed recording
system comes complete with a data
logger, weatherproof enclosure, a
three-cup anemometer and all the
necessary cabling to quickly get
up-and-running.
The logger can record up to
500,000 readings and the storage
medium is non-volatile, solid state
memory, providing maximum data
security even if the battery becomes
discharged. The small size of these
devices allows them to fit almost
anywhere.
The device can be started and
stopped directly from a computer
using our user-friendly software.
Data retrieval is simple. Simply plug
it into an available USB port and our
user-friendly software does the rest.
The software converts a PC into a
real-time strip chart recorder. Data
can be printed in graphical and
tabular format or exported to a text
or Microsoft Excel® file. The storage
medium is non-volatile solid state
memory, providing maximum data
security even if the battery becomes
discharged.
Specifications
Measurement Range: 0 to 100 mph (0 to 45 m/s) Resolution: 0.085 mph at 10 second reading interval Accuracy: ±2.0 mph from 0 to
10 mph; ±2.5% of reading from >10 to 100 mph Starting Threshold: 1.75 mph Reading Rate: 1 reading every second to 1 every 24 hours Memory: 500,000 readings; software configurable memory wrap
250,000 readings in multiple start/stop Memory Wrap Around: Yes Start Modes: Immediate start, delay start up to 18 months, multiple
pushbutton start/stop Stop Modes: Manual through software, timed
(specific date and time) Multiple Start/Stop Mode: Start and stop the device multiple
times without having to download data or communicate with a PC Multiple Start/Stop Mode Activation:
To Start the Device:
Press and hold the pushbutton for 5 seconds, the green LED will
flash during this time;
the device has started logging To Stop the Device:
Press and hold the pushbutton for 5 seconds, the red LED will flash
during this time.
The device has stopped logging. Real Time Recording: The device
may be used with PC to monitor and record data in real-time LED Functionality:
Green LED Blinks: 10 second rate to indicate logging; 15 second
rate to indicate delay start Red LED Blinks: 10 second rate to indicate low battery and/or full memory; 1 second rate to indicate an alarm condition Password Protection: An optional
password may be programmed into
the device to restrict access to
configuration options. Data may be
read out without the password Engineering Units: MPH, KPH,
M/S, KNOTS (software selectable) Battery Type: 3.6V lithium battery
(included); user replaceable Battery Life: 10 years typical,
dependent upon frequency and duty cycle Time Accuracy: ±1 minute/month
at 20ºC (68ºF), stand alone data logging Computer Interface:
USB (interface cable required); 115,200 baud Software: XP SP3/Vista and
Windows® 7 (32 and 64-bit) Anemometer Operating Environment: -55 to 60ºC
(-67 to 150ºF); 0 to 100%RH Operating Environment:
-20 to 60ºC (-4 to 150ºF), 0 to 100% RH non-condensing IP Rating: IP65 Anemometer Dimensions: 54 H x 192 mm D (2.1 x 7.5") Dimensions:
Data Logger:
74 H x 148 W x 39 mm D (2.9 x 5.8 x 1.5") Enclosure:
93 H x 62 W x 24 mm D (3.7 x 2.5 x 0.9") Weight: 513 g (18.1 oz) Material: ABS plastic
† Tous les Montants indiqués Dans EUR I> Notez: Comes complete with 3.6V lithium battery and OM-CP-IFC200 package which includes the Windows software, operator’s manual and 3.7 m (12') USB interface cable.