Layer N Banner

Industrial Ethernet to Serial Device Servers

OM-ES-500_Series

Ethernet to Serial Servers | OM-ES-500_Series

Ethernet to Serial Servers

5 ans de garantie CE
  • 1 Serial Port (OM-ES-511) or 2 Serial Ports (OM-ES-522) Software Selectable as RS232, RS422/485 Full Duplex, or RS485 Half Duplex
  • State-of-the-Art Autogating for Trouble Free RS485 Half Duplex Flow Control
  • Maximum Baud Rate 1,000,000 (1 MegaBaud), Custom Baud Rates
  • 10/100Base TX Ethernet Port
  • -30 to 80°C (-22 to 176°F) Temperature Range
  • User Friendly Interface
  • Web Configuration and RFC2217 Compliant Interface for Users Not Running Windows®
  • IP-30 Rated Non-Conducting Polyamide Enclosure
  • LED Status Indication
  • Integrated DIN Rail Mounting Kit
  • Serial Port Tunneling Allows Serial Cable Replacement Over Any Distance, No Software Required
Convertisseurs et produits de communication - Voir Les Produits Associés

Déscription

OM-ES-511 (1 serial port) and OM-ES-522 (2 serial ports) are software selectable as RS232, RS422/485 full duplex or RS422 half duplex and have removable screw terminals blocks for easy wiring, a slim ‘end on’ case and integral DIN rail mount. OM-ES-511 and OM-ES-522 have an operating temperature range of -30 to 80°C (-22 to 176°F) and with 5 to 30 Vdc dual input reverse polarity protected power supply making them perfect for industrial applications. Data transfer rates up to 1,000,000 baud, coupled with 1Mbit/s line drivers deliver uncompromising performance. OM-ES-511 and OM-ES-522 provide simple instant networked serial ports in demanding environments. Serial Port Tunneling allows serial cable replacement over any distance, no software required. Suitable to be wired into existing power and network infrastructure or can be used with a separate power supply.

Users of the Windows® Operating System Our software drivers give you local COM ports, allowing you to retain your existing software applications and connect to your devices over the network. COM Port can be assigned from COM 1 to COM 255 and the ethernet to serial device remembers your COM port assignment on reboots.

Web Interface Users (Linux®/Android™) A web interface allows secure configuration and control of the serial ports over a local network or the internet using any browser. You can access the device via TCP/ IP sockets from any networked device like a tablet for Android, PC or phone.

OM-ES-511 and OM-ES-522 Factory Floor Applications Factory floors can be harsh environments. Extreme temperatures can be generated in the manufacturing process, machinery can be noisy and dangerous and space is a premium. However engineers still need to be able to access and maintain equipment safely and without downtime.

As factories expand and modernize older equipment and remote devices need to be networked, but cabling can be expensive and impractical, especially over larger areas.

Once your serial equipment is connected to a OM-ES-511 or OM-ES-522 Ethernet to Serial device you have the option of accessing it over a local network or connecting it to the internet. The devices can be fitted in areas where it would be dangerous for workers to monitor while the factory line is in operation.

Manufacturing process and performance across a large site can be monitored and potential faults detected before they cause serious downtime costs. Use two devices back to back for serial tunnelling over Ethernet, for when you need to extend the reach of your serial cables.

Specifications
SERIAL PORTS
Ports: 1 port (OM-ES-511) or 2 ports (OM-ES-522) software selectable as RS232, RS422/485 full duplex, or RS485 half duplex
Connector: Removable screw terminal block connector–3.5 mm pitch
Power Input: Redundant DC dual power inputs, reverse polarity protected 5 to 30 Vdc
Power Consumption: 1.4 watt 60 mA@24V typical–2.9 watt maximum
Conductor Wire: 28 to 16 AWG, 0.14 to 1.5 mm (0.005 to 0.059") maximum
SERIAL PORT SETTINGS
Software Selectable as RS232, RS422/485 Full Duplex, or RS485 Half Duplex
Baud Rate: Any custom Baud rate between 60 to 1,000,000 (1 MegaBaud) can be selected
Data Bits: 5, 6, 7 or 8
Parity: Odd, even, none, mark or space
Stop Bits: 1, 1.5 or 2
Flow Control: XON/XOFF Software handshake or RTS/CTS hardware handshake
TX/RX Modes
RS232 Standard: RS232 allows point to point communication between 2 devices
RS422 Standard: RS422 allows one transmitter and up to 10 receivers with data transmitter rates up to 10 megabits per second for distances up to 40 feet and up to 100 Kilobits per second for distances up to 1219 m (4000'). To achieve good long distance noise immunity, 2 wires are used to carry each signal, configured as a twisted pair of cables. The TXD pair and RXD pair are used to carry the data while the RTS pair and CTS pair lines are used for handshaking. Thus 2 twisted pairs are used without handshaking and 4 twisted pair cable is used with handshaking both these schemes allow full duplex data communications.
RS485 Standard: RS485, based on the RS422 standard allows up to 32 driver/receivers pairs on a standard load or 128 low load devices per port can be connected. While only one of these should be transmitting data at any time, the rest can all simultaneously listen to the data. Handshaking is performed by software protocol. Two twisted pairs form a full duplex system. Often only one twisted pair cable is used as the TXD and RXD lines are tied together; this is known as half duplex mode. OM-ES-511 and OM-ES-522 implement a state of the art hardware autogating circuit ensuring error free communications in half duplex configurations.
Industrial Ethernet to Serial RS485: Receivers are 1/8th load allowing up to 256 nodes on the bus. Fail safe open circuit and short circuit protection, protects the Industrial ethernet to serial device server against wiring faults.
PORT SETTINGS–ETHERNET
Data Rate: 10/100 Mbps
Cabling: Normal/crossover auto-sensing (Auto-MDIX)
LED INFORMATION
Status LED
Green: Device ready
Flashing Yellow: Changing settings
Flashing Between Red and Green: Querying IP
Flashing Green/Red: User performing hard reset
Flashing Between Green and Red/Yellow: IP address diagnostic
Flashing Between Green and Yellow: Initialization diagnostic
SERIAL PORTS LEDs
Green Light On: Port open
Flashing Green: Data RX/TX
NETWORK LED
Green Light On: Link established
Flashing Green: Data RX/TX
ENVIRONMENTAL
Operating Temperature: -30 to 80°C (-22 to 176°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity: 5 to 95% RH (non-condensing)
Housing: NEMA 1 (IP-30) rated non-conducting polyamide case with integrated DIN rail mount
Weight: 21 g (0.74 oz)
Dimensions: 114.5 L x 22.6 W x 99 mm H (4.5 x 0.89 x 3.9")
SOFTWARE
Network Protocols: ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet, HTTP, RFC2217
Configuration Options: Windows operating system, Web Interface
OS Compatibility: Windows 2000, Windows XP, Windows Vista®, Windows 7, and Windows 8; Windows Server®
Connection to Network: Ethernet 10 Base T/100 Base TX
Performance: Throughput guaranteed minimum of 95% of theroretical bi-direction full duplex band width at 1 MBaud
INPUT
CTS False to Transmitter Stop: 3 characters maximum, 1.5 typical
XOFF Received to Transmitter Stop: 3 characters maximum, 1.5 typical
RS485 Autogating Turn Around Time: <1 bit time

Note: Android is a trademark of Google, Inc. Windows, Windows Vista, and Windows Server are registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.
Linux® is a registered trademark of Linus Torvalds in the U.S. and other countries.
Placez votre commande(Veuillez spécifier la référence du produit)

Ce que d'autres personnes ont acheté: quand vous voyez cette icône, cliquez dessus pour afficher une liste des produits que d'autres personnes ont achetés en plus de ce modèle.

Code d'article/ Desc.
Qté
Déscription
  
OM-ES-511
518.09
Stock: 1 semaine
 
Industrial ethernet to serial device server 1 port RS232/RS422/RS485
  
OM-ES-522
605.50
Stock: 1 semaine
 
Industrial ethernet to serial device server 2 port R4232/RS422/RS485
  
RAIL-35-1
17.49
Stock: 1 semaine
 
35 mm DIN rail, 1 m (3.3') length
Cliquez pour agrandir / réduire une liste d'achat connexeRAIL-35-2
RAIL-35-2
32.97
Stock: 1 semaine
 
35 mm DIN rail, 2 m (6.6') length
  
LP-PS-1524
Consultez le Service de ventes  
Stock: 
 
 
DIN rail mount 24Vdc power supply. 15W, 0.63 Amp, 25mm wide. Powered by 85 to 260 Vac, 47 to 63 Hz
Tous les Montants indiqués Dans EUR
Notez: Comes complete with utility software and operator’s manual on CD.
Exemple de commande: (1) OM-ES-511 Industrial ethernet to serial device server 1 port RS232/RS422/RS485, €518.09

Manuels de Produit:

Télécharger Quick Start - Industrial Ethernet to Serial Device Server
Télécharger Industrial Ethernet to Serial Device Server
Télécharger Quick Start - Industrial Ethernet to Serial Device Server
Télécharger Industrial Ethernet to Serial Device Server
We noticed you are from the US. Visit your local site for regional offers and live support.