Cookies sur les sites Web Omega
Nous utilisons des cookies sur ce site Web. Ces cookies sont indispensables au bon fonctionnement de notre site.
Si vous continuez sans modifier vos paramètres, nous supposerons que vous êtes heureux de recevoir tous les cookies de notre site Web.
Pour de plus amples informations à ce sujet, veuillez cliquer ici
Fermer
Panier  |  Contact  | 
NUMÉRO VERT 0805 541 038
INTERNATIONAL+33 01 57 32 48 17
Layer N Banner

Hygienic Pt100 Sensors with Integral Cable. For use in CIP Clean-In-Place Applications

PRS-CB Series Hygienic RTD Sensors

Direct Immersion Hygienic Pt100 Sensors with Integral Cable. For Food, Dairy, Brewing and Pharmaceutical Applications | PRS-CB Series Hygienic RTD Sensors

287,18 PRS-3-100-A-S-0300-D1-CB-120

  • 1/4" Diameter Probe Design for Standard Duty, or
    3/8" to 3/16" Stepped Probe Design For Heavy Duty Applications
  • Probe Lengths of 3", 4", 5" and 6" Available From Stock, Other Lengths Also Available
  • Process Connection is a 1½"-16 AMP Tri-Grip™ (Tri-Clamp® Compatible) Standard, Other Sizes and Styles Available. Flanges Conform to ASME BPE-2007 Standard to Assure Trouble Free Interchangeability.
  • Sensor Can be Used in Sanitary, Hygienic and Clean-In-Place Food, Dairy, Beverage and BioPharmaceutical Processes
  • 316L SS Wetted Surfaces with 32 µinch or Better Surface Finish
  • 4-Conductor, 120" Long PFA Cable with Molded Nylon Strain Relief Standard
  • -50 to 200°C (-58 to 392°F) Temperature Range
  • 4-Wire Pt100 Class A Platinum RTD Sensor (100.00±0.06Ω at 0°C) Standard
  • Compatible with 3-Wire and 2-Wire RTD Instruments and Transmitters
Sanitaire - Voir Les Produits Associés

Déscription

Click on this link if you need more information about Sanitary Sensors.

Sanitary Temperature Sensor Specifications Include:
  • 316L stainless steel process wetted surfaces with surface finishes of 32 microinches or better.

  • Probe lengths of 3, 4, 5 or 6 inches available from stock, other lengths available as special orders.

  • Sensor Output is a 4-wire, 100 ohm, Class A, Platinum RTD meeting the requirements of IEC 60751.

  • These sensors can be used with 2-wire or 3-wire systems see information below.

  • Insulation resistance: 100 megohms minimum at 100 VDC.

  • Thermal response time of less than 2.5 seconds in water flowing at 3 ft/sec (63% response).


  • This Sanitary Temperature Sensor containes a PT100 Platinum RTD element and is designed for use in Food, Dairy, Beverage and BioPharmaceutical Clean-In-Place (CIP) type applications. The sensor includes a 1½" 16AMP process connection that conforms to ASME BPE-2007 for easy installation using industry standard gaskets and clamps. Standard Duty sensors are available with ¼" diameter probes, and Heavy Duty sensors are available with a stepped 38" to 316" diameter probe. This sensor is provided with a 120" long, 4-conductor, #26AWG stranded nickel plated copper, PFA insulated and jacketed cable with a strain relief for convenient connection to control or monitoring equipment.

    Food process hygienic temperature sensors can be used to aid food safety inspection compliance and verification of time temperature control. Combined with a chart recorder model CTXL you can temperature monitor a CCP ( Critical Control Point) or sanitation time and move toward a HACCP (Hazard Analysis Critical Control Point) compliance plan.

    In addition to the standard 1½-16AMP process connection, these can be provided in the following sizes and styles:
    Process ConnectionModel Number Code
    3/4"-16AMP-B1-
    1" and 1½"-16AMP-D1-
    2"-16AMP-E1-
    2½"-16AMP-F1-
    3"-16AMP-G1-
    4"-16AMP-H1-










    If you need a process connection that is not listed above, please contact our sales department for availability.

    These sanitary sensors are supplied standard as 4-wire assemblies with two red wires and two white wires. When used in 3-wire applications, cut off one white wire making sure that it will not contact any terminals or metal surfaces (note: twisting the two white wires together will reduce the lead wire resistance on one side of the sensing element by half adversely affecting the accuracy of the reading). When used in 2-wire applications, cut off one white wire and one red wire (note: in 2-wire applications, twisting the two same-colored wires together at the terminals will not adversely affect your sensor accuracy since both wires will be affected by the reduction in resistance).

    These sensors are also available in Thermistor and Thermocouple styles to accommodate any process input requirement.
    Placez votre commande(Veuillez spécifier la référence du produit)
    Code d'article/ Desc.
    Qté
    Déscription
    Standard Duty ¼" Diameter Probe Design
    PRS-3-100-A-S-0300-D1-CB-120
    287.18
    Stock: 6 semaines
     
    3" long standard duty probe
    PRS-3-100-A-S-0400-D1-CB-120
    281.65
    Stock: 6 semaines
     
    4" long standard duty probe
    PRS-3-100-A-S-0500-D1-CB-120
    281.65
    Stock: 6 semaines
     
    5" long standard duty probe
    PRS-3-100-A-S-0600-D1-CB-120
    281.65
    Stock: 6 semaines
     
    6" long standard duty probe
    Heavy Duty 3/8" to 3/16" Stepped Probe Design
    PRS-3-100-A-H-0300-D1-CB-120
    348.51
    Stock: 6 semaines
     
    3" long heavy duty probe
    PRS-3-100-A-H-0400-D1-CB-120
    348.51
    Stock: 6 semaines
     
    4" long heavy duty probe
    PRS-3-100-A-H-0500-D1-CB-120
    348.51
    Stock: 6 semaines
     
    5" long heavy duty probe
    PRS-3-100-A-H-0600-D1-CB-120
    348.51
    Stock: 6 semaines
     
    6" long heavy duty probe

    Trier par Référence

    Code d'article
    Qté
    Code d'article
    Qté


    Tous les Montants indiqués Dans EUR
    Notez: Contact sales for pricing and to order probes with additional sheath and/or cable lengths
    Exemple de commande: (1) PRS-3-100-A-S-0400-D1-CB-120 Sanitary RTD sensor with 4-wire Pt100, Class A accuracy element, ¼, €281.65

     Constructeur de référence

    Construisez votre numéro de pièce ci-dessous
    Descriptions des options de:


    (1) Nominal Element Resistance Select:
    100 pour 100 ohm @ 0 C (standard)
    1000 pour 1 kohm @ 0 C

    (2) Probe Diameter Select:
    S pour Standard Duty 1/4 inch
    H pour Heavy Duty 3/8 to 3/16 inch stepped probe

    (3) Probe Length Select:
    0300 pour 3 inch length
    0400 pour 4 inch length
    0500 pour 5 inch length
    0600 pour 6 inch length

    (4) Sanitary Flange (Cap) Size Select:
    D1 pour 1-1/2 inch Tri-Grip Flange (standard)
    B1 pour 3/4 inch 16AMP Tri-Grip Flange
    E1 pour 2 inch 16AMP Tri-Grip Flange
    F1 pour 2-1/2 inch 16AMP Tri-Grip Flange
    G1 pour 3 inch 16AMP Tri-Grip Flange
    H1 pour 4 inch 16AMP Tri-Grip Flange

    (5) Lead Wire Cable Length Select:
    120 pour 120 inch/10 ft (standard)
    144 pour 144 inch/12 ft
    180 pour 180 inch/15 ft
    240 pour 240 inch/20 ft
    Notez: Toutes les combinaisons peuvent ne pas être valables, vérifiez la fiche technique pour les références valables.
    We noticed you are from the US. Visit your local site for regional offers and live support.