Cookies sur les sites Web Omega
Nous utilisons des cookies sur ce site Web. Ces cookies sont indispensables au bon fonctionnement de notre site.
Si vous continuez sans modifier vos paramètres, nous supposerons que vous êtes heureux de recevoir tous les cookies de notre site Web.
Pour de plus amples informations à ce sujet, veuillez cliquer ici
Fermer
Panier  |  Contact  | 
NUMÉRO VERT 0805 541 038
INTERNATIONAL+33 01 57 32 48 17
Layer N Banner

PX291  - Discontinued

PX291

 | PX291

  • Voltage or Current Outputs
  • Low Power Consumption
  • No Moving Parts to Wear
  • Position Insensitive
  • Reliable Long Term Stability
  • Rugged Flame Retardant Case

Déscription

The PX291 Series of differential pressure transmitters is designed to measure low pressures while using little power. A selection of ranges is available to meet most industrial and laboratory applications. The transmitters are housed in a flame-retardant, glass-reinforced polyphenylene oxide case. Electrical connections are made by means of a 3.8" terminal with #6 screws. There are no moving parts and the transducers are virtually position insensitive. The span and zero settings are made via 20-turn potentiometers, for easy and precise adjustments. The pressure sensing element is a differential capacitive cell for the low pressure ranges from 0.1 to 5 inH2O and a piezoresistive chip for ranges above 5 inH2O. Both sensors ensure reliability and long-term stability.

SPECIFICATIONS
General: Measures differential, gage pressure or vacuum
Excitation: 11 to 32 Vdc reverse polarity protected
Voltage Output Models: 0 to 5 Vdc 3-wire, source or sink 3.5 mA, short circuit protected, current draw = 10 mA
Current Output Models: 4 to 20 mA, output limited to approximately 3.85 mA at low end and 25 mA at high end Maximum Current Loop Resistance: RL = (Vs - 11) x 50
Accuracy: ±1% includes linearity, hysteresis
Calibration: NIST-traceable
Operating Temperature: 0 to 45°C (32 to 115°F)
Temperature Effects:
Zero: ±0.05%/°C
Span: ±0.02%/°C
Operating Humidity Range: 10 to 90% non-condensing
Shock Resistance: 10 g (11 ms)
Vibration Resistance: 5 g to 50 Hz
Overpressure: See order chart for maximum safe momentary overpressure
Media Compatibility: Suitable for air or inert gas
Pressure Connection: 3.16" Dia. tube connections with integral filters at both ports, suitable for 1.8" ID TygonR or polyurethane tubing (3 to 4 mm) or 1.4" OD polyethlene tubing (6 mm)
Electrical Connection: External 3.8" terminal strip with #6 screws
Case Material: Flame-retardant, glass-reinforced polyphenylene oxide
Dimensions: 36 H x 76 W x 131 mm L (1.4H x 3.0W x 5.15"L)
Weight: 190 g (6.72 oz)

OFFSET OPTIONS
If the measured differential pressure is expected to go from positive to negative, a transducer with offset (elevated zero) should be ordered. The standard models in the order chart have no offset (i.e., at zero differential pressure, the output is 0 Vdc or 4 mA). 2 offset options are available: gAh 1.4 Span Offset At zero differential pressure, the output is 1.25 Vdc or 8 mA
Allowable pressure excursion: -33% to 100% of range gBh 1.2 Span Offset At zero differential pressure, the output is 2.5 Vdc or 12 mA
Allowable pressure excursion: -100% to 100% of range
Examples: PX291-001WD5V-A will have a range of 1"
Placez votre commande(Veuillez spécifier la référence du produit)
Code d'article/ Desc.
Qté
Déscription
PX291-001WDI
Consultez le Service de ventes  
Stock: 
 
 
has a range of 1.00 inH2O at 20 mA and 0 differential pressure at 4 mA,
PX291-001WD5V
Consultez le Service de ventes  
Stock: 
 
 
has a range of 1.00 inH2O at 5 Vdc and 0 differential pressure at 0 Vdc
Tous les Montants indiqués Dans EUR
Notez: See Specifications for desription of the elevated zero option.

 Constructeur de référence

Construisez votre numéro de pièce ci-dessous
Descriptions des options de:


(1) Range Select:
0.1 pour 0-0.1
0.2 pour 0-0.2
0.3 pour 0-0.3
0.5 pour 0-0.5
001 pour 0-1
002 pour 0-2
003 pour 0-3
005 pour 0-5
010 pour 0-10
020 pour 0-20
030 pour 0-30
050 pour 0-50
100 pour 0-100

(2) Units Select:
WD pour Range in inH20
D pour Range in psid

(3) Output Select:
5V pour 0 to 5 Vdc
I pour 4 to 20 mA

(4) Offset Options Select:
pour Leave Blank For No Offset
-A pour 1/4 Span Offset
-B pour 1/2 Span Offset
Notez: Toutes les combinaisons peuvent ne pas être valables, vérifiez la fiche technique pour les références valables.