Cookies sur les sites Web Omega
Nous utilisons des cookies sur ce site Web. Ces cookies sont indispensables au bon fonctionnement de notre site.
Si vous continuez sans modifier vos paramètres, nous supposerons que vous êtes heureux de recevoir tous les cookies de notre site Web.
Pour de plus amples informations à ce sujet, veuillez cliquer ici
Fermer
Panier  |  Contact  | 
NUMÉRO VERT 0805 541 038
INTERNATIONAL+33 01 57 32 48 17

RTDCAP Series

Platinum RTD Capsules | RTDCAP Series

Platinum RTD Capsules

  • 4 Temperature Ranges Available
  • 100 or 1000 Ω Available
  • Ceramic (Alumina) or Plastic Capsules
  • 540° C, 1000° F Range
  • 2-, 3- and 4-Wire Configurations as Noted
  • Moisture Resistant Available in Some Models
  • Fiberglass, Polyimid or PTFE Leads, Standard Lead Length is 40 Inches
Sondes, éléments et ensembles RTD (PT100) - Voir Les Produits Associés

Déscription

Ready to use platinum RTD capsules have insulated lead wires welded and anchored internally. No splicing to fragile elements is required. This construction assures reliable rugged embedment, insertion or probe assembly. Tip diameters from 0.086 to 0.125". Standard sensors and encapsulation materials rated up to 540°C (1000°F). Choose the moisture resistant version for condensing conditions.

Specifications
Standard Lead Length: 40 Inches
Operating Temperature Range:
    TFE Leads: -200 to 260°C (-320 to 500°F)
    Polyimide Leads: -200 to 350°C (-320 to 660°F)
    Fiberglass Leads: -75 to 510°C (-100 to 950°F)
    Moisture Resistant: -50 to 200°C (-60 to 390°F)
Sensing Element: International grade thin film platinum, a = 0.00385 Ω/Ω/°C per IEC 60751
Ice Point Resistance: 100.00±0.06Ω or 1000.0±0.6Ω at 0°C
Time Constant (Water at 3'/Second):
    0.086 Diameter = 0.5 seconds
    0.098 Diameter = 0.6 seconds
    0.125 Diameter = 0.8 seconds
    0.187 Diameter = 1.5 seconds
Self-Heating: Less than 15 mW/°C
Interchangeability/Accuracy: Class A (±0.15+.002*|t|°C [where |t|= absolute value of temperature in °C]) between -50 and 300°C, Class B above and below these temperatures
Long Term Stability: Better than 0.05°C (0.02% of resistance) per 5 years, -50 to 300°C (-58 to 572°F), 0.25°C per year to 540°C (1004°F)
Insulation Resistance: Greater than 50 Megohms at 50 Vdc at 25°C (77°F)
Maximum Current: 100 Ω = 5 mA, 1000 Ω = 2 mA for limited self-heating; also suitable as self-heated sensors
Recommended Current: 1 mA maximum for temperature sensing
Case Materials: Alumina on 0.125 and 0.086 diameter, Polyimide [350°C (662°F)] on 0.098 diameter
Lead Materials, Nickel-Coated Copper-Insulated:
    28 AWG Fiberglass: Rated to 510°C (950°F)
    28 AWG TFE: Rated to 260°C (500°F)
    28 AWG Polyimide: Rated to 350°C (660°F)
Placez votre commande(Veuillez spécifier la référence du produit)
Code d'article/ Desc.
Qté
Déscription
Standard Lead Length is 40 Inches
0.086" (2.2 mm) Diameter
RTDCAP-100A-1-A086-060-K-40
346.44
Stock: 1 semaine
 
100 Ω RTD, 0.086" diameter x 0.6" long alumina with 28 AWG polyimide leads, 350°C (660°F), 2-wire only
RTDCAP-1KA-1-A086-060-K-40
278.46
Stock: 8 semaines
 
1000 Ω RTD, 0.086" diameter x 0.6" long alumina with 28 AWG polyimide leads, 350°C (660°F), 2-wire only
0.098" (2.5 mm) Diameter
RTDCAP-100A-2-P098-050-K-40
230.79
Stock: 1 semaine
 
100 Ω RTD, 0.098" diameter x 0.5" long polyimide with 28 AWG polyimide leads, 350°C (660°F), 3-wire only**
RTDCAP-100A-2-P098-050-T-40
222.53
Stock: 1 semaine
 
100 Ω RTD, 0.098" diameter x 0.5" long polyimide with 28 AWG TFE leads, 260°C (500°F), 3-wire only**
RTDCAP-1KA-2-P098-050-K-40
226.33
Stock: 1 semaine
 
1000 Ω RTD, 0.098" diameter x 0.5" long polyimide with 28 AWG polyimide leads, 350°C (660°F), 3-wire only**
RTDCAP-1KA-2-P098-050-T-40
226.33
Stock: 14 semaines
 
1000 Ω RTD, 0.098" diameter x 0.5" long polyimide with 28 AWG TFE leads, 260°C (500°F), 3-wire only**
0.125" (3.2 mm) Diameter
RTDCAP-100A-3-A125-060-T-40
216.57
Stock: 1 semaine
 
100 Ω RTD, 0.125" diameter x 0.6" long alumina with 28 AWG TFE leads, 260°C (500°F), 4-wire only**
RTDCAP-100A-2-A125-060-T-40-M
224.61
Stock: 1 semaine
 
100 Ω RTD, 0.125" diameter x 0.6" long alumina with 28 AWG PFTE leads, 200°C (390°F), 300 psi seal, moisture resistant, 3-wire only**
RTDCAP-100A-2-A125-060-F-40
224.61
Stock: 6 semaines
 
100 Ω RTD, 0.125" diameter x 0.6" long alumina with 28 AWG fiberglass leads, 510°C (950°F), 3-wire only**
RTDCAP-1KA-3-A125-060-T-40
220.28
Stock: 1 semaine
 
1000 Ω RTD, 0.125" diameter x 0.6" long alumina with 28 AWG TFE leads, 260°C (500°F), 4-wire only**
RTDCAP-1KA-2-A125-060-F-40
220.28
Stock: 1 semaine
 
1000 Ω RTD, 0.125" diameter x 0.6" long alumina with 28 AWG fiberglass leads, 510°C (950°F), 3-wire only**
Tous les Montants indiqués Dans EUR
Notez: ** Note: 3- and 4-wire sensors can be modified by the customer for 2- and 3-wire applications by cutting off unneeded lead wires.
There is a 25 pc minimum on non-standard lengths; check with Sales Dept for pricing.
Exemple de commande: (1) RTDCAP-100A-1-A086-060-K-40 100 O RTD, 0.086, €346.44
We noticed you are from the US. Visit your local site for regional offers and live support.